Naneum instruments

Nano-ID NPS 500


The Nano-ID NPS500 sets a new standard for high sensitivity and selectivity aerosol measurements. It provides the ability to measure particle size distributions over a range of 5 nm to 500 nm with 128 user-selectable channels. Read More

Nano-ID Select

The Nano-ID Select is a wide-range sampler and is unique in that it spans the entire aerosol range from 2 nm up to 20 μm. Read More

 

 


Nano-ID Select in Iceland during the volcanic eruption of Eyjafjallajökull in 2010

The Nano-ID Select wide-range aerosol sampler was employed to sample and fractionate aerosols generated during the eruption of Eyjafjallajökull in 2010. This event, although relatively small for volcanic eruptions, caused enormous disruption to air travel across Europe over a period of several days in April 2010 (figure 5.1).

Figure 5.1: Ash being pumped into atmosphere during the Eyjafjallajökull eruption. Photograph: Jon Gustafsson/AP

Aerosol samples collecting using the Nano-ID Select were used to measure mass-size distributions and to evaluate the chemical composition of ash particles. The instrument was deployed in the field at locations close to the volcano, and was powered by a mobile AC power source (figure 5.2)

Figure 5.3 shows a typical SEM image of particles collected by the Nano-ID Select close to the volcano. The SEM image reveals a complicated population of irregularly shaped aerosol particles.  Below the SEM image is an XRF spectrum showing the chemical composition of the particle indicated by the small white square in the SEM image. The XRF spectrum reveals the presence of a number of elements including S, Fe, Al, Ca, K, Mg, O, C and Na.

This case study demonstrates the wealth of information that can be obtained using the Nano-ID Select wide range aerosol sampling system. It is a unique instrument that can be used to obtain mass-size distributions of the various constituents of airborne aerosols. In addition, when used with the optional portable power supply, it can be easily deployed at more remote locations.

Figure 5.2: The Nano-ID Select sampling at a site in Iceland.


Figure 5.3: A typical SEM image obtained from samples collected using the Nano-ID Select at a site in Iceland.  Below is an XRF elemental composition spectrum obtained taken at the spot indicated by the small white square in upper-right image.
SEM images and XRF spectrum: Prof. Throstur Thorsteinsson

 